Find the item
Search by name, brand or item code. Tap Ask price to send an item on WhatsApp.Tap Add, then send your list on WhatsApp.
Shop by range
Quick guides
What contractors ask us every day, from our suppliers' catalogues and the Energy Commission wiring guideline. Tap a topic.
Which cable and breaker do I need?
Start with the appliance. Then check the cable data from the makers' own data sheets. Tell us what you are wiring and we help you choose.
Cable, breaker and RCCB for common appliances (single phase) · Kabel dan pemutus ikut peralatan · 按电器选电线和开关
| Appliance | Cable | MCB | RCCB | Also fit |
|---|---|---|---|---|
| Lights and ceiling fans | 1.5mm² | 6A or 10A | 100mA | |
| 13A sockets, radial (up to 50m²) | 2.5mm² | 20A | 30mA | |
| 13A sockets, ring (up to 100m²) | 2.5mm² | 32A | 30mA | |
| Inverter washing machine | On a 13A socket circuit | 30mA Type A | ||
| Aircond 1 to 2HP | 4mm² (2.5mm² also common for 1 to 1.5HP) | 20A Type C | 100mA, Type A for inverter units | Isolator at the outdoor unit |
| Aircond 2.5 to 3HP | 4 to 6mm² | 32A Type C | 100mA, Type A for inverter units | Isolator at the outdoor unit |
| Water heater (about 3.6kW) | 4mm² (2.5mm² also common) | 20A | 10mA | 20A double-pole switch |
| Cooker or induction hob (up to about 7kW) | 6mm² | 32A | 100mA | 45A double-pole switch |
| Garden and pathway lights | 1.5mm², bigger for long runs | 6A or 10A | 10mA | Weatherproof fittings and boxes |
| EV charger (7kW, single phase) | 6mm², 10mm² for long runs | 40A | 30mA Type B, or Type A with 6mA DC protection | Its own circuit. Follow the charger manual |
| Pump or motor | From the amps on its nameplate | Type C | Ask us | Contactor and overload relay for bigger motors |
General guide only. It assumes copper PVC cable in conduit on a short run. If the appliance manual asks for more, follow the manual. A registered wireman (Pendawai Elektrik, ST) must design, install and test the wiring. We supply the parts and can recommend a wireman. Based on the Energy Commission domestic wiring guideline (GP/ST/No.39/2024). Kitchen: give the fridge, microwave and kettle their own sockets. Your registered wireman plans the number of points and gives you the installation cost.
The right part for the job · Barang yang sesuai · 选对配件
| Job | What to use |
|---|---|
| Aircond outdoor unit | A weatherproof isolator next to the unit. 20A up to 2HP. 32A for 2.5 to 3HP. See isolators |
| Water heater in a bathroom | A 10mA RCCB, plus a 20A double-pole switch outside the shower area. See RCCBs |
| Outdoor or wet-area socket | A weatherproof socket with a cover, on a 30mA RCCB. See weatherproof sockets |
| Machines and site power | Industrial plug and socket. Blue 3-pin for single phase 230V. Red 4- or 5-pin for 3-phase 400V. See industrial plugs |
| Motors and pumps | A contactor with an overload relay (a DOL starter), on a Type C MCB. Size it from the nameplate amps. See contactors |
| Outdoor lights on a schedule | A photocell for dusk to dawn, or a timer. See photocells |
| Many LED fittings on one circuit | A Type C MCB, so the start-up surge does not trip it. See MCBs |
| Lightning-prone area | A surge protection device (SPD) in the DB board. See SPD |
| Long cable run | Often one size bigger than the table, because of voltage drop. Send us the length and the load. Ask on WhatsApp |
Not sure? Send us a photo of the label or the drawing on WhatsApp. We reply within 30 minutes during opening hours.
Amps a PVC flexible cord can carry (single-phase, three-phase after the dot).
Example: a 2kW heater on 240V draws about 8.3A, so 1.5mm² (16A) is enough. Hot place: × 0.82 at 40°C. Long runs: ask us or your electrician about voltage drop. Source: Fajar Cables (IEE Wiring Regs, 17th ed.).
Multi Wire single core PVC cable, 450/750V. Overall diameter helps you choose conduit and casing size.
Source: Multi Wire Product Specification (MS 2112-3). Armoured and multi-core sizes are in our product ranges, under Cables & wires.
Approvals held by Multi Wire, the main cable brand we stock.
Copies of current certificates are available on request for project submissions. Ask on WhatsApp.
Popular for this job: Cable and breakers for the job
Pilihan popular · 热门选择. Tap a photo for details, or add it to your quote list.
Images are for reference only. Gambar untuk rujukan sahaja. 图片仅供参考。
RCCB (ELCB) and MCB: which one?
From the Energy Commission domestic wiring guideline (GP/ST/No.39/2024) and the EPS catalogue.
RCCB sensitivity · Kepekaan ELCB · 漏电开关灵敏度
| Rating | Use it for |
|---|---|
| 10mA | Water heaters, pool lights, garden and pathway lights, wet areas |
| 30mA | 13A socket circuits (hand-held appliances) |
| 100mA | Lights, fans, aircond and other circuits. A common main RCCB for homes |
| 300mA | Fire protection on 3-phase and commercial incomers |
Choose RCCB amps at least as high as the breaker before it (63A main → 63A RCCB). 2 pole for single phase, 4 pole for 3-phase. Type A for inverter aircond and washing machines. EV chargers need Type B, or Type A with 6mA DC protection. Press the test button every month.
MCB trip curve · how big a start-up surge it ignores.
| Type | Trips at | Use it for |
|---|---|---|
| B | 3 to 5 × rating | Lights, sockets, heaters |
| C | 5 to 10 × | Aircond, motors, pumps, many LED fittings on one circuit |
| D | 10 to 20 × | Transformers, welders |
Breaking capacity 6kA suits most homes and shops. Near a big transformer, ask us about 10kA.
- JMS MCB: 6kA, Type B and C, IEC 60898. 1 to 4 pole, 6A to 63A.
- NGPL RCCB (ELCB): IEC 61008-1. 2 and 4 pole, 16A to 63A (100A in its own range). 10, 30, 100 and 300mA. Type AC and Type A.
- HM1 MCCB: IEC 60947-2. 63A frame 30kA at 415V. 100A frame 35kA or 50kA.
- VCT-T2 surge protector: Type 2, 20kA nominal, 40kA max, 1.5kV protection level, IEC 61643-11.
Popular for this job: RCCB, MCB and isolators
Pilihan popular · 热门选择. Tap a photo for details, or add it to your quote list.
Images are for reference only. Gambar untuk rujukan sahaja. 图片仅供参考。
Choose the right light
From the Philips Lighting catalogue 2025/26. We stock Philips bulbs, downlights, tubes and floodlights at the counter.
Base
Screw-in E27 (standard), E14 (small) or E40 (high-bay). Push-in spots GU10 or GU5.3 (MR16).
Brightness
Look at lumens on the box. For LED bulbs, roughly: 1–4W soft · 5–7W comfortable · 8–19W bright · 22–50W extra bright.
Colour
Not sure? Bring the old bulb to the counter or send a photo on WhatsApp. We match the base and brightness for you.
Three bulbs giving about the same light (410 to 485 lumens).
Power used
Lifetime
Source: Philips Lighting Product Catalogue 2025/26 (Signify).
Philips Meson IO recessed downlights, drawn to scale. Measure the ceiling hole (cut-out) before you buy.
Meson IO: EyeComfort interlaced optics, 3 colours, 25,000 hours, 3-year warranty (Philips).
Choose an LED tube in 3 steps (Philips catalogue 2025/26).
Size
2ft (600mm) or 4ft (1200mm). Measure the old tube to know which one you have. All T8, G13 pins.
Brightness
2ft: 8 to 10W, about 800 to 1,050 lumens. 4ft: 16 to 25W, about 1,800 to 3,000 lumens.
Colour
3000K warm white · 4000K cool white · 6500K cool daylight.
| Philips tube | Size | Watts · lumens |
|---|---|---|
| Ecofit LED tube | 2ft | 8W · 800 lm |
| Ecofit (industrial pack) | 2ft / 4ft | 9W · 900 lm / 18W · 1,800 lm |
| Ecofit High Output | 2ft / 4ft | 10W · 1,050 lm / 20W · 2,100 lm / 22W · 2,300 lm |
| LED Tube HO+ | 4ft | 25W · 3,000 lm |
Swap a fluorescent tube for an Ecofit LED tube (no rewiring in most fittings):
- Turn off the power.
- Remove the old fluorescent tube.
- Remove the old starter.
- Insert the LED (EMP) starter that comes with the tube.
- Fit the Philips LED tube.
- Turn the power back on.
New LED casing, or an old fitting rewired without the ballast:
- Philips Ecofit T8 tubes are single-end. Live and neutral go to the lampholder at one end only.
- Cut the wire to the other end, so only one side is connected. The pins at that end just hold the tube.
- Take out the old ballast and starter. Mark the fitting LED only, so nobody fits a fluorescent tube back.
Check the tube label first. "Single-end" means power at one end only. A registered wireman should do the rewiring. LED tubes last about 15,000 hours and contain no mercury.
Which Philips light for which space (Philips Professional catalogue 2026 and consumer catalogue 2025/26).
| Space | Light to use | Why |
|---|---|---|
| Living room, bedroom, dining | LED downlights and ceiling lights | Soft, even light with a wide beam; Meson Comfort has CRI 90 |
| Office, school, clinic, meeting room | LED panel light (RC091V slim) | 8.5mm slim, about 100 lm/W, fits a ceiling grid |
| Shop display, showroom | Track spotlights (ST033T), LED strips | Aim light at products |
| Factory, warehouse, workshop, high ceiling | Highbay (BY229, 60W, 8,000 lm) | Hangs from a hook, pipe or bracket |
| Car park, basement, garage | Waterproof batten (WT068C IP66/IK08, or WT069C with LED tubes) | Water and dust proof |
| Billboard, landscape, building front | Floodlight (BVP150 / BVP151 / BVP158) | Aluminium housing, built-in surge protection |
| Road, driveway, parking | Road light (BRP121) | Pole or wall mounted |
| Garden | Garden spotlight (BGP150), solar lights | Use a 10mA RCCB on garden lighting |
What makes a good LED light (Philips catalogue 2025/26).
| Look for | What it means |
|---|---|
| EyeComfort | No visible flicker (Pst LM ≤ 1.0), even light, less glare. Easier on the eyes for long reading or work |
| CRI (colour rendering) | From 1 to 100. Higher shows colours more naturally. Meson Comfort downlights are CRI 90; most others CRI 80 |
| Lumens per watt | Brightness for the power used. Old bulb about 10 lm/W, LED bulb about 85 lm/W, Philips Ultra Efficient about 210 lm/W |
| Lifetime | LED bulbs 8,000 to 15,000 hours, downlights up to 30,000, Ultra Efficient up to 50,000. Heat shortens LED life, so leave the fitting room to cool |
| Beam angle | Downlights spread about 100° for general light; spotlights are narrower to light one spot |
| Warranty | Ultra Efficient 5 years; Meson downlights 3 years; Ecofit tubes 1 year |
Example: a 2.3W Ultra Efficient bulb gives about the same light (485 lm) as an old 40W bulb (410 lm).
Popular for this job: Lights our customers buy most
Pilihan popular · 热门选择. Tap a photo for details, or add it to your quote list.
Images are for reference only. Gambar untuk rujukan sahaja. 图片仅供参考。
Which DB board size?
EPS modular metal clad boards. Count the MCB ways you need, add the RCCB and main switch, then about 25% spare.
| Model | Rows · ways | W × H × D (mm) |
|---|---|---|
| ES 10 | 1 row · 10 ways | 300 × 218 × 95 |
| ES 14 | 1 row · 14 ways | 370 × 218 × 95 |
| ES 18 | 1 row · 18 ways | 430 × 218 × 95 |
| ES 22 | 1 row · 22 ways | 490 × 218 × 95 |
| Model | Rows · ways | W × H × D (mm) |
|---|---|---|
| EM-2 | 2 rows · 30 ways | 400 × 360 × 120 |
| EM-2M | 2 rows · 18 ways | 400 × 360 × 120 |
| EM-3 | 3 rows · 45 ways | 400 × 610 × 120 |
| EM-3M | 3 rows · 38 ways | 400 × 610 × 120 |
| EM-4 | 4 rows · 60 ways | 400 × 750 × 120 |
| EM-4M | 4 rows · 53 ways | 400 × 750 × 120 |
| Model | Rows · ways | W × H × D (mm) |
|---|---|---|
| EL-2 | 2 rows · 36 ways | 470 × 360 × 120 |
| EL-2M | 2 rows · 24 ways | 470 × 360 × 120 |
| EL-3 | 3 rows · 54 ways | 470 × 610 × 120 |
| EL-3M | 3 rows · 46 ways | 470 × 610 × 120 |
| EL-4 | 4 rows · 72 ways | 470 × 750 × 120 |
| EL-4M | 4 rows · 64 ways | 470 × 750 × 120 |
| EL-5 | 5 rows · 90 ways | 470 × 890 × 120 |
| EL-5M | 5 rows · 82 ways | 470 × 890 × 120 |
| Model | Rows · ways | W × H × D (mm) |
|---|---|---|
| EM 3A | 3 rows · 45 ways | 400 × 500 × 120 |
| EM 4A | 4 rows · 60 ways | 400 × 640 × 120 |
| EM 5A | 5 rows · 75 ways | 400 × 780 × 120 |
| EL 3A | 3 rows · 54 ways | 470 × 500 × 120 |
| EL 4A | 4 rows · 72 ways | 470 × 640 × 120 |
| EL 5A | 5 rows · 90 ways | 470 × 780 × 120 |
| EL 6A | 6 rows · 108 ways | 470 × 920 × 120 |
"Compact" boards are shorter for the same number of ways. Boards join top, bottom or side by side. Built to IEC 60439-3 (BS 5486-12).
Popular for this job: DB boards and what goes inside
Pilihan popular · 热门选择. Tap a photo for details, or add it to your quote list.
Images are for reference only. Gambar untuk rujukan sahaja. 图片仅供参考。
Conduit and trunking sizes
From the Feema and Smartube catalogues. Most people ask in inches at the counter, so both are shown.
| Size | Outside Ø (mm) | Inside Ø min | Wall min |
|---|---|---|---|
| 20mm (¾") | 19.7 to 20.04 | 16.9 | 1.25 |
| 25mm (1") | 24.6 to 25.05 | 21.5 | 1.35 |
Feema rigid uPVC conduit, BS EN 61386-21, SIRIM. 2.9m lengths, white, bundles of 50. 1¼" is 32mm.
| Code | W × H (mm) | Inches |
|---|---|---|
| C 001 | 20 × 10 | ¾" |
| C 002 | 27 × 13 | 1" |
| C 003 | 30 × 13 | 1¼" |
| C 004 | 40 × 16 | 1½" |
| C 005 | 40 × 20 | 1½" × ¾" |
| C 006 | 50 × 16 | 2" |
| C 007 | 50 × 32 | 2" × 1" |
| C 008 | 50 × 55 | 2" × 2" |
| C 009 | 75 × 55 | 3" × 2" |
| C 010 | 100 × 55 | 4" × 2" |
| C 011 | 100 × 75 | 4" × 3" |
C 001 to C 005 are mini trunking (casing). C 006 to C 011 are modular trunking.
| Smartube colour | Used for |
|---|---|
| Red | Fire alarm and security systems |
| Orange | Lighting, fibre optic, machinery |
| White | Blends with light-coloured walls |
| Clear (silver) | Standard, conventional use |
Hot-dip galvanised steel with a slip coat inside for easy wire pulling. Made to BS 31, BS 4568 / MS IEC 61386, UL 797 (EMT) and UL 1242 (IMC).
Popular for this job: Conduit, boxes and casing
Pilihan popular · 热门选择. Tap a photo for details, or add it to your quote list.
Images are for reference only. Gambar untuk rujukan sahaja. 图片仅供参考。
We watch copper, so you get a fair cable price.
Copper is the main cost in electrical cable, so cable prices follow the copper market. We monitor the copper price closely and pass on supplier price changes fairly, to give you the best price we can.
Harga kabel mengikut harga tembaga. Kami memantau harga tembaga untuk memberi anda harga terbaik.
电线价格跟随铜价。我们密切留意铜价,给您最合理的价钱。
Copper price, 2026 to today
Brands we carry





















Tap a brand to see the items we stock. Brand names are trademarks of their respective owners.
Supplier catalogues · preview, full catalogue on request
All 21 catalogues, by range · on request
- Switches & socketsSchneider Electric
- Circuit protection & boardsEPS, Hager, Isotech
- CableMulti Wire, Fajar
- Conduit & trunkingFeema, Smartube, Underfloor trunking
- LightingPhilips, Nikkon
- Emergency lightingEconlite, PEL series
- FansUMS, Lemax
- Control & signallingSchneider Electric, MS-390
Tell us the brand, range or model. We send the catalogue to you on WhatsApp. 需要完整目录,请 WhatsApp 我们。
Visit the counter.
Gibson Electrical Trading supplies electrical materials from our shop on Jalan Mawar, off Raja Uda. Contractors, factories, renovators and homeowners come to us for wiring, protection and lighting parts. Bring your list, a sample or a photo. We will find it, or source it for you.
欢迎光临门市。带上清单、样品或照片,我们帮您找。
送货到北海、大山脚、北赖、诗布朗再也和槟岛,1至3个工作日。RM500 以上先付款免运费;RM500 以下请门市自取。
SCAN OR TAP TO WHATSAPP US